The power at which a rider's second ventilatory threshold shows up on a ramp test changed by 45 watts depending on how fast the pedals turned, according to a small study in the Journal of Science and Cycling. Nine recreational cyclists in Belgium did the same ramp test three times, at 70, 90 and 110 revolutions per minute (rpm), and the higher the cadence, the lower the wattage at which their thresholds appeared.

The paper was published on November 1, 2026, in volume 15, issue 2 of the journal, so it is about two weeks old. The authors are Matthew Van Dyck, Sem De Vuyst, Mauro Sannen, Jan Boone and Kevin Caen, with Van Dyck listed at Ghent University.

What the researchers did

Each of the nine participants was a healthy male recreational cyclist, averaging 22.4 years old, 74.9 kilograms and 182 centimeters. Each completed three ramp incremental tests to exhaustion, one at each cadence, in a randomized order. Breath-by-breath gas exchange was recorded, and the power at each threshold was corrected for the lag between a change in workload and the body's gas-exchange response.

The first ventilatory threshold (VT1) marks the end of easy, sustainable effort. The second (VT2) marks the move into hard effort and is the lab marker closest to what many riders call threshold power or FTP. Peak power output (PPO) is the highest wattage reached before the rider could not continue.

What changed with cadence

Average results rose and fell in step with cadence across every measure the team reported:

  • Power at VT2: 284 W at 70 rpm, 260 W at 90 rpm, 239 W at 110 rpm.
  • Power at VT1: 218 W, 198 W and 182 W. Only the gap between 70 and 110 rpm was statistically significant.
  • Peak power: 424 W, 414 W and 399 W.
  • Time to exhaustion: 747, 727 and 696 seconds, which is 51 seconds shorter at 110 rpm than at 70 rpm.

The 45-watt gap at VT2 is about 16 percent of the 70 rpm value. Peak power moved less, by 25 W, or about 6 percent. Across the range, the fitted slope worked out to roughly 1.15 W lost at VT2 for each added rpm, compared with 0.96 W at VT1 and 0.66 W at peak power. In other words, the thresholds were more sensitive to cadence than the top end of the test was.

Peak oxygen uptake (VO2peak) did not differ significantly between cadences, at 4.2, 4.0 and 3.9 liters per minute from slowest to fastest pedaling. The riders' aerobic ceiling was not the thing that moved; the wattage at which they crossed the markers below it was.

Why this matters if you train by zones

Power zones and FTP estimates are usually built from one test, and the cadence used during that test is rarely recorded. Based on these numbers, a rider who tests while spinning near 110 rpm could come out with a threshold figure tens of watts lower than the same rider testing near 70 rpm, even though nothing about their fitness changed. Zones set from that figure would then be lower or higher than they should be for riding at a different cadence.

The authors conclude that cadence meaningfully affects ramp-test outcomes and that training intensities set from thresholds may produce a different physiological load depending on the cadence used. The paper does not establish which cadence is most efficient, least fatiguing or best for endurance performance, so it does not point to a correct number to pedal at.

For indoor riders, where the trainer or bike controls the wattage and the rider picks the cadence, the finding bears on repeat testing. Comparing a new test with an old one only makes sense if both were done at a similar cadence, and a drop in estimated threshold between two tests could partly reflect a change in pedaling speed rather than in fitness.

Limits of the study

  • Nine participants, all young men, so the size of the effect in women, older riders or well-trained racers is not shown.
  • Only three cadences were tested, and each was held fixed. Most riders vary cadence naturally during a test.
  • The article page does not state the funding source, the ramp protocol's starting wattage and step size, or the type of ergometer, and no DOI is listed there.
  • The report was reached through the journal's open-access page and abstract; the methods and discussion sections in the full PDF could not be read for this article.

What to do with it

The practical step is recordkeeping: note the average cadence next to every ramp test or FTP result, and use a similar cadence when retesting. The full paper is open access on the Journal of Science and Cycling website, and its methods section is where to check the ramp protocol before applying the numbers to your own testing.

Sources